Transport Ventilators   |   Air/Oxygen Blenders   |   MRI Ventilators

Any Questions? +1-800-224-6633

Our Products - Other Blenders - High Flow-High/Low-Mid Flow

« Back
2002F70D - High Flow Blender with 0-70 lpm Flow Meter

2002F70D - High Flow Blender with 0-70 lpm Flow Meter

The 2002F70D is the ideal model for use with a high flow cannula system. It comes pre-installed with a 0-70 lpm flow meter close mounted to the left side of the blender. It has a very slim profile compared to others. There is no bleed flow on this blender, so no wasted gas usage. It has an accuracy range from 15-120 lpm.

» Learn More

2004F7015 High/Low Blender with 70 and 0-15 lpm Flow Meter Blender

2004F7015 High/Low Blender with 70 and 0-15 lpm Flow Meter Blender

The 2004F7015 is the ultimate configuration for the high flow nasal cannula setup. It features a 0-70 lpm flow meter on the left side and a 0-15 lpm flow meter on the right side. This will allow it to be used for the full patient population. The right side flow meter is installed with an integrated bleed control switch. The flow meter can be rotated forward, thus turning off the bleed flow when it is not needed. Then simply rotating the flow meter to the upright position allows lower flow usage on the right side.

» Learn More

2001 and 2001M Blenders (MRI)

2001 and 2001M Blenders (MRI)

The 2001 and 2001M (the 2001M is the MRI Conditional version for use in the MRI Suite) provide higher flow capabilities (up to 120 lpm) than the Low Flow Blenders (30 lpm). In general, this model is well suited for providing a blended flow to equipment that uses higher than 30 lpm flows. It features a bottom 50 psi DISS port for making this connection. The right side port is most often used to install a 0-15 lpm flow meter. Just be aware that using the right side port activates the 12 lpm bleed flow. If the primary purpose of this blender is for use with a 0-15 lpm flow meter, it might be better to look into a Low Flow model.

» Learn More

2004 High/Low Blender (3 ports)

2004 High/Low Blender (3 ports)

The 2004 is a High-Low Flow Blender (with the emphasis on High). It has 3 DISS ports (left, right and bottom). If anything is screwed onto the right side port, the 12 lpm bleed flow is activated and the blender's accuracy range is from 2-108 lpm.  This bleed flow will be active whenever the blender is connected to an air and oxygen gas sourse (even if the flow meters are turned off). If nothing is connected to the right side port (the bleed is not active), the accuracy range of the blender is between 15-120 lpm.

» Learn More

2001K High/Low Blender with Bleed Control Switch

2001K High/Low Blender with Bleed Control Switch

The 2001K features the same basic specifications as the 2001 model. It features a single 50 psi DISS oxygen port on the bottom and a bleed control switch on the right side. This allows the user to activate the bleed flow of 12 lpm when gas usage will below 15 lpm or disable it when usage will be above 15 lpm.

» Learn More

2001F High/Low Blender with Integrated Bleed Switch/0-15 lpm Flow Meter

2001F High/Low Blender with Integrated Bleed Switch/0-15 lpm Flow Meter

The 2001F features a 50 psi DISS oxygen fitting on the bottom port and a 0-15 lpm flow meter close mounted to an integrated bleed control switch. This allows for higher flow usage from the bottom port and when not needed, the 12 lpm bleed flow can be disabled by rotating the flow meter forward. Then when flows below 15 lpm are needed and the flow meter is rotated to the upright position, the bleed flow is automatically activated. If this is only needed for flows of 15 lpm or less, a Low Flow model should be considered.

» Learn More

2002 High Flow Blender

2002 High Flow Blender

The 2002 is specifically designed for uses where higher flows are required. It provides a single 50 psi DISS port on the bottom has an accuracy range from 15-120 lpm and does not have a bleed flow.

» Learn More