Transport Ventilators   |   Air/Oxygen Blenders   |   MRI Ventilators

Any Questions? +1-800-224-6633

Our Products - Low Flow Air/Oxygen Blenders (For the NICU and L & D)

« Back
NEO<sub>2</sub> Blend

NEO2 Blend

The NEO2 Blend was designed specifically with the NICU in mind. It comes with two flow meters close mounted to the body of the blender and takes up far less wall space than when flow meters are attached to a standard Low Flow blender. It comes in 3 different versions depending on what kind of flow usage is required. The left side flow meter of all models has a 0-15 lpm flow meter (most often used for a resuscitation bag), while the left can be configured with a 0-1 lpm, 0-3 1/2 lpm or a 0-15 lpm. The other unique and cost saving feature is: When the flow meter on the right side is not in use, the 3 lpm bleed flow can be disabled by rotating the flow meter forward.

» Learn More

2003FL-Low Flow Blender w/ Flow Meter and Bleed Control

2003FL-Low Flow Blender w/ Flow Meter and Bleed Control

This model is ideal for the Labor and Delivery settting where generally only a single 0-15 lpm flow meter is needed for resuscitation purposes. It comes with the 0-15 lpm flow meter close mounted to the body of the blender. This can be important, since more often, the medical equipment is hidden in small alcoves behind picture frames (until needed), where space is very limited. The bleed control switch allows the bleed flow to be disabled. This can save costs by allowing the blender to be connected and ready, but not be wasting 3 lpm of gas 24 x 7 when not in use. This may be absolutely necessary in units where air may not be piped in.

» Learn More

2003K-Standard Low Flow Blender with Bleed Control

2003K-Standard Low Flow Blender with Bleed Control

The 2003K features a DISS oxygen port on the left side that allows the user to install a flow meter of their choosing. On the right side is a bleed control knob that allows the user to activate the bleed flow (3 lpm) in situations where accuracy is desired for uses below 3 lpm.There is also an oxygen DISS port on the bottom for additional usage.

» Learn More

2003-Standard Low Flow Blender

2003-Standard Low Flow Blender

The 2003 is the standard low flow blender that most people are familiar with. It consists of oxygen DISS ports on both the right and left side. The user can install the flow meters of their choice.

Note: When a flow meter is installed on the right side port, the bleed flow (3 lpm) is active (and remains active until either the right side flow meter is removed, or the blender is disconnected from the gas supply). Because of the presence of the DISS port and the minimum distance required by a flow meter with a DISS fitting, the overall side-to-side width of this configuration is considerably wider than the NeO2 Blend model.

» Learn More

2003P-Standard Low Flow Blender w/3 Ports

2003P-Standard Low Flow Blender w/3 Ports

The 2003P features the standard low flow blender (with an oxygen DISS fitting on both the left and right sides) with an additional oxygen DISS port on the bottom for added connectivity.The bleed flow (3 lpm) is activated when a flow meter is installed on the right side port, and remains active until either the right side flow meter is removed, or the hoses are disconnected from the gas source.

» Learn More

2003M-Low Flow Blender for MRI

2003M-Low Flow Blender for MRI

The 2003M is the standard low flow blender that most people are familiar with, only it is MR Conditional for use in the MRI area. It consists of oxygen DISS ports on both the right and left side. The user can install the flow meters of their choice.

Note: when a flow meter is installed on the right side port, the bleed flow (3 lpm) is active (and remains active until either the right side flow meter is removed, or the blender is disconnected from the gas supply). Because of the presence of the DISS port and the minimum distance required by a flow meter with a DISS fitting, the overall side-to-side width of this configuration is considerably wider than the NeO2 Blend model.

» Learn More

2003F Blender (Operating Room)

2003F Blender (Operating Room)

The 2003F blender was designed specifically for the operating room environment. It is a low flow blender that is configured with a 0-15 lpm flow meter installed. This allows a blended gas source to be delivered to a patient and minimizes the potential build-up of oxygen under the patient drape. The flow meter is attached to an integrated switch that allows the bleed flow (3 lpm) to only be active when the flow meter is in the upright position, and in use. This way, when the OR is not in use, the flow meter can be rotated forward and there is no waste of gas unnecessarily. The positioning of the flow meter in the OFF position can also be visualized without having to enter the room.

» Learn More

2003FFN

2003FFN

Primarily used with pediatric patients. Same as the Neo2 Blender model 2003FF with on/off bleed control switch except it has different size flow meters.  
0-8 LPM with white label
2-28 LPM with white label
(this model has DISS gas connections)

» Learn More

2003FFH

2003FFH

Primarily used with pediatric patients. Same as the Neo2 Blender model 2003FF with on/off bleed control switch except it has different size flow meters.
0-8 LPM with white label
2-28 LPM with white label
(this model has NIST gas connections)
 

» Learn More